Last week we experienced a hard problem to debug, but easy to solve. It was hard to debug because it didn’t happen in development or test environment, only in production environment after a deploy and the error message we got was not helping at all.

What was happening was that after the deploy to production the site crashed and gave us this message:
”Subquery returned more than 1 value. This is not permitted when the subquery follows =, !=, <, <= , >, >= or when the subquery is used as an expression.”
With the stacktrace:

“[SqlException (0x80131904): Subquery returned more than 1 value. This is not permitted when the subquery follows =, !=, <, <= , >, >= or when the subquery is used as an expression.]
   System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection, Action`1 wrapCloseInAction) +1767866
   System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception, Boolean breakConnection, Action`1 wrapCloseInAction) +5352418
   System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj, Boolean callerHasConnectionLock, Boolean asyncClose) +244
   System.Data.SqlClient.TdsParser.TryRun(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj, Boolean& dataReady) +1691
   System.Data.SqlClient.SqlDataReader.TryHasMoreRows(Boolean& moreRows) +322
   System.Data.SqlClient.SqlDataReader.TryReadInternal(Boolean setTimeout, Boolean& more) +230
   System.Data.SqlClient.SqlDataReader.TryNextResult(Boolean& more) +189
   System.Data.SqlClient.SqlDataReader.NextResult() +28
   System.Data.ProviderBase.DataReaderContainer.NextResult() +19
   System.Data.Common.DataAdapter.FillNextResult(DataReaderContainer dataReader) +51
   System.Data.Common.DataAdapter.FillFromReader(DataSet dataset, DataTable datatable, String srcTable, DataReaderContainer dataReader, Int32 startRecord, Int32 maxRecords, DataColumn parentChapterColumn, Object parentChapterValue) +233
   System.Data.Common.DataAdapter.Fill(DataSet dataSet, String srcTable, IDataReader dataReader, Int32 startRecord, Int32 maxRecords) +421
   System.Data.Common.DbDataAdapter.FillInternal(DataSet dataset, DataTable[] datatables, Int32 startRecord, Int32 maxRecords, String srcTable, IDbCommand command, CommandBehavior behavior) +173
   System.Data.Common.DbDataAdapter.Fill(DataSet dataSet, Int32 startRecord, Int32 maxRecords, String srcTable, IDbCommand command, CommandBehavior behavior) +316
   System.Data.Common.DbDataAdapter.Fill(DataSet dataSet) +88
   EPiServer.DataAccess.<>c__DisplayClassa.<DeleteDB>b__9() +240
   EPiServer.Data.Providers.<>c__DisplayClass7`1.<ExecuteTransaction>b__6() +200
   EPiServer.Data.Providers.SqlDeadlockRetryPolicy.Execute(Boolean isInTransaction, Func`1 method) +716
   EPiServer.Data.Providers.SqlDatabaseHandler.ExecuteTransaction(Func`1 action) +302
   EPiServer.DataAccess.ContentTypeDB.DeleteDB(Int32 pageTypeID) +171
   EPiServer.DataAccess.ContentTypeDB.Delete(ContentType contentType) +278
   EPiServer.DataAbstraction.DefaultContentTypeRepository.Delete(ContentType contentType) +174
   EPiServer.DataAbstraction.BlockTypeRepository.Delete(BlockType blockType) +40
   EPiServer.DataAbstraction.RuntimeModel.ContentTypeSynchronizer`2.Delete(T contentType) +104
   EPiServer.DataAbstraction.RuntimeModel.ContentTypeModelRegister`2.CommitTypes(Boolean deleteUnusedTypes) +365
   EPiServer.DataAbstraction.RuntimeModel.ContentTypeModelScanner`3.Sync(Boolean commitChanges) +131
   EPiServer.Initialization.ModelSyncInitialization.Initialize(InitializationEngine context) +580
   EPiServer.Framework.Initialization.<>c__DisplayClass5.<Initialize>b__4() +56
   EPiServer.Framework.Initialization.ModuleNode.Execute(Action a, String key) +73
   EPiServer.Framework.Initialization.ModuleNode.Initialize(InitializationEngine context) +141
   EPiServer.Framework.Initialization.InitializationEngine.InitializeModules() +445
   EPiServer.Framework.Initialization.InitializationEngine.Initialize(HostType hostType) +256
   EPiServer.Framework.Initialization.InitializationModule.Initialize(HostType hostType) +344
   EPiServer.Framework.Initialization.InitializationModule.FrameworkInitialization(HostType hostType) +78
   EPiServer.Global..ctor() +83
   SITENAME.Web.Global..ctor() +29
   ASP.global_asax..ctor() in c:\Windows\Microsoft.NET\Framework\v4.0.30319\Temporary ASP.NET Files\root\8fc7b944\c53070aa\App_global.asax.0.cs:0”

In itself the message or stack trace was not helping us much at all more than telling us that something happen when EPiServer was initializing the site. Luckily for us, we had only made a couple of changes between the last deployment and this (the great thing of agile development!) so looking what those check in was about and the error message said we could narrow it down to a rename of a content type.
Why didn’t it happen in development or test? That is a good question and nothing I have the answer to, if you do, please tell me in a comment. I checked the database and there were no content created for this content type.
To solve the problem, we just added a migration to the project that looked like this:

    public class MigrateEducationListBLock : MigrationStep
    {
        public override void AddChanges()
        {
            ContentType("LocationEducationFavoritesListBlock")
                .UsedToBeNamed("EducationListBlock");
        }
    }
Apr 15, 2014

Comments

Apr 15, 2014 05:33 PM

Did you specify GUIDs on your content types before renaming them?

valdis
valdis Apr 15, 2014 06:32 PM

Interesting. We haven't come across this error in rename cases..

Henrik Fransas
Henrik Fransas Apr 15, 2014 08:49 PM

Daniel: The first version was created without a GUID specified and when we did the rename we specified the GUID but with a new one, thinking that it would just delete the old contenttype. The first version was a "to early checkin..." that had gone all the way to production.

Valdis: It was the first time for us also, and bare in mind that it did not show in development or test, only in production so it is very strange.

Apr 16, 2014 10:08 AM

Ah ok! Yeah, specifying PageTypes without GUID and then renaming them will definitely get you into trouble. Been there, done that :)

Apr 16, 2014 10:11 AM

Be careful about changing namespace as well if you don't have GUIDs specified for your pagetype btw. DO use GUIDs...always...

Henrik Fransas
Henrik Fransas Apr 16, 2014 10:36 AM

Thanks Daniel, yes, thankfully we will learn from our mistake :)

Please login to comment.
Latest blogs
Fix your Search & Navigation (Find) indexing job, please

Once upon a time, a colleague asked me to look into a customer database with weird spikes in database log usage. (You might start to wonder why I a...

Quan Mai | Apr 17, 2024 | Syndicated blog

The A/A Test: What You Need to Know

Sure, we all know what an A/B test can do. But what is an A/A test? How is it different? With an A/B test, we know that we can take a webpage (our...

Lindsey Rogers | Apr 15, 2024

.Net Core Timezone ID's Windows vs Linux

Hey all, First post here and I would like to talk about Timezone ID's and How Windows and Linux systems use different IDs. We currently run a .NET...

sheider | Apr 15, 2024

What's new in Language Manager 5.3.0

In Language Manager (LM) version 5.2.0, we added an option in appsettings.json called TranslateOrCopyContentAreaChildrenBlockForTypes . It does...

Quoc Anh Nguyen | Apr 15, 2024